HomeMy WebLinkAboutAppeals.Minutes.04-19-2002 MINUTES BOARD OF APPEALS City of Cape Girardeau P.O. Box 617 Cape Girardeau, Missouri 63702-0617 April 19, 2002 The Board of Appeals met Thursday,April 11, 2002 at 7:00 p.m. in the Council Chambers, City Hall 401 Independence St.. Members Present: Dave Pfeiffer,Joe Burton, Farris Nabors,Tony Sebek, Paul Grebe, and Dave Alberson. Members Absent: Michael Annis (alternate) and Tom Phillips (alternate) Call to order at 7:05 p.m. by Dave Pfeiffer, Vice-chairman. Roll Call. re) Motion was made by"Tony Sebek to accept the minutes from the Mardi 14, 2002 meeting. Dave Alberson seconded the motion, motion passed 6-0 in favor. Discussion of the 2000 International Fire Codes: Mike Morgan, Fire Marshall and Mike Lackman, Fire Chief was present to discuss the 2000 International Fire Code. Chapter 9 Fire Protection System. The board wanted to look over the exceptions for this chapter from the last meeting. The Chief wanted to delete all the exceptions, which would give die lire department more protection after these buildings are built. Presently the designers can design the buildings to meet the exceptions without considering the lire department in the design. After the last meeting the fire chief looked over the exceptions to a greater extent after the board objected to deleting all exceptions in the chapter. He has indicated a few sections with exceptions he would like to have amended. Section 903.2.2 Group E. Exception: Where each classroom has at least one exterior exit door at ground level. The reason for deleting this exception is because the chief said this type of structure there should be no exceptions, this is an education structure and they should all be equipped with automatic sprinkler systems. Section 903.2.7 Group R-1. Exception: I) Where guestrooms are not more than three stories above the lowest level of exit discharge and each guestroom has at least one door leading directly to an exterior exit access that leads directly to approved exits. 2) A residential sprinkler system installed in accordance with Section 903.3.1.2 shall be allowed In buildings. or portions thereof;of Group R-1. This is another example where they could BOARD OF APPEALS MINUTES April 11, 2002 Page 2 install a R-13 for life safety for occupants and does not take in account the safety of the fire department having to enter the building after the occupants are safely out of the building. Section 903.2.8 Group R-2. Exception: A residential sprinkler system installed in accordance with Section 903.3.1.2 shall be allowed in buildings, or portions thereof,.of Group R-2 The same examples pertain to this exception as in the previous exception in section 903.2.7. The tire department still enters these buildings after the occupants are safely out of the building, the firefighters needs protection also. Section 903.3.1.2 NFPA 13R sprinkler systems. Where allowed in buildings of Group R, up to and includinglour Stories In height, automatic sprinkler systems shall be installed throughout in accordance with NEPA 13R. Chief Lackina.n would like this section deleted, because this would eliminate all the 13R systems in the exceptions. Section 903.3.5.2 Secondary water supply. A secondary on-site water supply equal to the hydraulically calculated sprinkler demand, including the hose stream requirement, sign C tegoiy C;D,E or Pas determined by the International Building Code. The secondary water supply shall have duration not less than 30 minutes. Exception: Existing buildings. This is a section required in high rise buildings only, is there any high rise buildings in Cape? Yes the towers at SEMO are considered high rise. Section 907.3.1.7 Group R-1 Exception: Buildings that have a single-station smoke alarms rris meeting or exceeding the requirements of Section 9072.10.1 and where the fire ahem system includes at least one manual lire alarm box per floor arranged to initiate the alarm. Delete this exception because once again there is life style issues at boarding and rooming houses and early detection on all floors is critical, if only one fire alarm box is required, they don't always use the door where the alarm box is located. Section 907.3.1.8 Group R-2 Exception #1: Where each living unit is separated from other contiguous living units by lire bathers having a lire-resistance rating of not less than hour;; and where each living unit has either its own independent exist or its own independent stairway or ramp discharging at grade. The fire chief indicated he felt this exception was just too risky. Section 907.3.1.9 Group 4 Exception #1: Where there are interconnected smoke alarms meeting the requirements of Section 9072.10 and there is at least one manual fire alarm box per floor arranged to sound continuously the smoke alarms. He also indicated he felt this exception was just too risky. Section 912.2 Location. Where respect to hydrants, driveways, building and landscaping; lire (Apartment collllectlons shall be so located that lire apparatus and hose connected to supply the system will not obstruct access to the buildings for other lire apparatus. The location of lire department connections shall be approved The fire chief would like to see this amended to 75 feet instead of the present 100 feet, and language to include a strobe light. The board indicated if the 100 feet presently used for this section, is not written in ordinance form, then the ordinance should be rewritten. Mike Morgan will check on information for the board if there is a city ordinance about the distance the connections are located for access. BOARD OF APPEALS MINUTES April 11, 2002 Page 3 Tony Sebek indicated he had a problem with some of the exceptions because the designers would not be aware of the exceptions being amended or deleted until the project was in review by the city. Dave Alberson asked if all the changes could be provided in a condense version so the designers could have the information before the review. Chief asked if the changes could be added to the city's web site. Dianna will check on the possibly when the codes has been approved. A board member asked about the 13R systems, the Chief said he did not know the cost, but did know they were designed for quick installation. The system is designed for protection of the property and not for the fire department to get in the building. Dave Alberson would like to see the option of case by case basis before the exception is deleted completely, maybe used for a smaller building. Chapter 33 Explosives and Fireworks. Chief Lachman met with Eric Cunningham, City Attorney for this meeting about deleting or amending sections of this chapter. Eric agreed with the Board, the chapter could not be deleted. The chief has some recommendations about amending sections of the chapter. Section 3304 Put language for existing quarries to comply with this chapter and the NFPA for storage and handling of explosive materials. Section 3305 Manufacture, assembly and testing of explosives, explosive material and fireworks it would have to say Section 3306.4.1 Fire department recommends that the Group R-3 structures should be deleted or amended. Section 3306.4.2 Once again this section mentions Group R-3 structures, the Chief would like to have this deleted or amended. Section 3306.5.2.1 Storage of quantities for smokeless propellant, paragraph 3 and die subsections, Chief believes 5,000 pounds is excessive amount for storage and for black powder not to exceed 50 pounds. Section 3306.4.1 The main objective is with the storage in Group R-3, in multi-family storage should not be allowed. Section 3308 Fireworks. There is an ordinance that covers fireworks; wording would need to be changed in die ordinance. A memo will be sent to Eric about changing the city ordinance about fireworks. The chief said the code would be amended with the city ordinance in the fireworks section. Chapter 1 Section 105 Permits. The information attained from other lire departments was from the St. Louis arca. No fire department is following the true intent of the code for this section; the city is using a permit system now for business licenses, but until more could be trained for inspections this section will not be used as intended by the code. As for as the fees the City Council would have to implicate with a vote, the board can only recommend Ices for permits in the lire code. Tony Sebek made a recommendation to amend Chapter 33, sections 3304, 3305, 3306.4, 3306.5.2 paragraph 3, 3306.5.2.2 would read not greater than 50 pounds and 3306.5.2.3 anything over 50,000. Tony made a motion of Chapter 33 of the 2000 International Fire raN Code of the varies sections of deletions of explosives, small arms ammunitions and small BOARD OF APPEALS MINUTES April 11, 2002 Page 4 arms powder recommend by the Fire Chief. Dave Alberson seconded the motion, motion passed 6-0 in favor. Tony Sebek made a motion to amend Chapter 33 of the 2000 International Fire Code, section 3308 Fireworks Display; but Tony rescinded this motion for Chapter 33. The Chief suggested it should be Section 3301.1.3 of Chapter 33. Tony Sebek made a motion for Chapter 33, section 3301.1.3 Fireworks. Deleting exceptions 1 and 2, and amending exceptions 3 and 4 to the city ordinance on fireworks. Farris Nabors seconded the motion, motion passed 6-0 in favor. Chapter 9 Fire Protection Systems. Dave Alberson made a motion to modify Chapter 9 with the following changes: 903.2.2 Eliminate the exception. Where each classroom has at least one exterior exit door at ground level 903.2.7 Eliminate exception #1. Where gziestrooms are not more than three stories above the lowest level of exit discharge and each guestrooln has at least one door leading directly to an exterior exit access that leads directly to approved exits. 903.2.8 Eliminate the exception. A residential sprinkler system installed in accordance with Section 903.3.1.2 shall be allowed in buildings, or portions thereof;of Group R-2. 903.3.1.2 Delete this section. NFPA 13R sprinkler systems; Where allowed in buildings of Group R, up to and including four stories i i height, automatic sprinkler systems shall be installed throughout in accordance with NFPA 13 R. 903.4.2 Amend section to include visual and audible signals. Alarms:Approved audible devices shall be connected to every automatic sprinkler system. Such sprinkler water-flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed In the system. Alarm devices shall he provided toll the exterior of the building in an approved location. Where a lire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system. 907.3.1.7 Delete the exception. Buildings that have single-station smoke alarms meeting or exceeding the requirements of Section 9072.10.1 and where the fire alarm system includes at least one manual lire alarm box per floor arranged to initiate the alarm. 907.3.1.8 Delete exception #1. Where each living unit is separated from other contiguous living units by fire barriers having a fire-resistance rating of not less than hour, and where each living unit has either its own independent exit or its own Independent stairway or rasp dischwgung at grade. 907.3.1.9 Delete exception #1. Where there are interconnected smoke alarms meeting the requirements of Section 907.2.10 and there is al least one manual lire alarm box per floor arranged to sound continuously the smoke alarms. Tony Sebek seconded the motion, motion passed 6-0 in favor. BOARD OF APPEALS MINUTES April 11, 2002 Page .5 Tony Sebek made a motion to recommend the adoption of the 2000 International Fire Code, with the exceptions noted. Dave Alberson seconded the motion, motion passed 6-0 in favor. Discussion opened on the 2002 National Electrical Code, does the board want to include the 2002 NEC or stay with the 1999 NEC? The board previously approve the adoption of the 1999 NEC should they now switch to the 2002 NEC, since the new code books is now an option. If they would stay with the 1999 version they would always be at least two years behind in adopting the newest code. The major changes were in the 1999 code book and Dave Pfeiffer found very kw changes to the 2002 version. All references to the 1999 NEC in the building code would have to be changed to 2002 NEC. Tony Sebek made a motion to adopt the 2002 National Electrical Code and all references to the 1999 National Electrical Code amended to the 2002 National Electrical Code. Farris Nabors seconded the motion, motion passed 6-0 in favor. Discussion of the recommendations for the procedure for Adopting New Codes. Dave Pfeiffer indicated he had a problem with a couple of the recommendations, not enough board member to create sub-committees to review codes; and item #5 if not completed in six months the codes would automatic would be adopted. This procedure will be saved until the 2003 Codes are available, and further discussion can be tabled until then. r4) Being there was no other business at this time, a motion was made to adjourn. The meeting adjourned at 8:47 p.m. The next meeting of the Board of Appeals is scheduled for May 9, 2002. Respectfully Submitted, Dave Alberson Secretary